Key points
- Engineered stone benchtops, panels and slabs have been banned in every Australian jurisdiction since 01/07/2024, and became prohibited imports on 01/01/2025.
- Removing, repairing, making minor modifications to or disposing of legacy engineered stone is still allowed, but in most places you must notify your WHS regulator first.
- You must assess in writing whether processing of any crystalline silica substance is high risk, and assume it is high risk if you cannot tell.
- High-risk work needs a silica risk control plan, accredited or regulator-approved silica training, air monitoring and health monitoring.
- Air and health monitoring records must be kept for 30 years, and training records for 5 years after the worker leaves.
What does the engineered stone ban cover?
On 13/12/2023, WHS ministers agreed to ban engineered stone. From 01/07/2024, the Commonwealth and every state and territory made it an offence for a business (a PCBU) to carry out, or direct or allow a worker to carry out, the manufacture, supply, processing or installation of engineered stone benchtops, panels or slabs. From 01/01/2025, those products also became prohibited imports under regulation 5M of the Customs (Prohibited Imports) Regulations 1956.
Under the model WHS Regulations, engineered stone is an artificial product that contains at least 1% crystalline silica (weight for weight), is made by combining natural stone materials with other constituents such as water, resins or pigments, and becomes hardened. A product has to be a benchtop, panel or slab and meet all three parts of that definition to be banned.
Safe Work Australia lists products that are not engineered stone for this purpose:
- concrete and cement products, bricks, pavers and similar blocks
- ceramic wall and floor tiles, and roof tiles
- sintered stone and porcelain products, provided they do not contain resin
- grout, mortar, render and plasterboard
- finished items that are not meant to be processed further, such as engineered stone sinks or garden ornaments
What legacy engineered stone work is still allowed?
Legacy engineered stone is stone that is already installed, and for disposal it also includes uninstalled stock such as a stockpile. Businesses can still remove, repair, make minor modifications to or dispose of it. Before doing that work, a PCBU must notify the WHS regulator and make sure the processing is controlled, for example with wet cutting, on-tool dust extraction or local exhaust ventilation. Victoria does not require notification, but controlled processing still applies.
Check your regulator's process. SafeWork NSW, for example, asks businesses to notify annually with an estimate of the next 12 months of work, before starting or directing workers, whenever the work changes, and immediately if legacy stone was processed without knowing it.
One trap: re-installing a benchtop counts as installation, even if you do not cut it. Safe Work Australia calls this an unintended consequence. Interim exemptions allowing re-installation in specific circumstances have been granted in all jurisdictions, so ask your regulator before you lift and refit.
Silica duties reach far beyond benchtops
From 01/09/2024, the model WHS Regulations added duties for processing any crystalline silica substance (CSS), meaning any material with at least 1% crystalline silica. Processing includes using power tools or mechanical plant to crush, cut, grind, trim, sand, abrasively polish or drill a CSS, as well as quarrying, tunnelling, mechanical screening and roadheader excavation.
Safe Work Australia says this can happen across manufacturing, stonemasonry, construction, tunnelling, demolition, mining and quarrying. Its examples include brick, concrete or stone cutting, cutting and laying pavers, angle grinding and jack hammering concrete or masonry, foundry casting and pottery. If your workers process these materials, the rules below apply to you, not just stonemasons.
Is your silica work high risk?
You must assess whether each processing task is high risk and write the assessment down. If you cannot work it out, you must assume it is high risk until a later assessment shows otherwise.
The assessment considers the form and amount of crystalline silica in the material, the hazards and how often and how long people are exposed, whether airborne respirable crystalline silica is reasonably likely to exceed half the exposure standard, past air and health monitoring, and past silica-related illness. You cannot count respirators or administrative controls when judging likely airborne levels, and using on-tool extraction does not on its own make a task low risk.
Example: A tiling business dry cuts porcelain tiles with an angle grinder on most jobs and has never tested the air. The owner cannot show exposure is low, so the work must be treated as high risk until monitoring proves otherwise.
The high-risk checklist: plan, train, monitor, record
Once processing is high risk, these duties apply. Our silica and engineered stone awareness course explains how the high-risk decision is made and the monitoring, reporting and training duties that follow.
- Silica risk control plan: document each high-risk task, its assessment and controls, how you will check the controls work, and consult workers and any HSRs. Give it to workers before they start. On construction work, a SWMS can stand in if it covers the same content.
- Training: give crystalline silica training to every worker involved in, or at risk from, high-risk processing. It must be nationally accredited or approved by your WHS regulator, and cover the health risks and the proper use of controls.
- Air monitoring: monitor respirable crystalline silica in workers' breathing zones. The exposure standard is 0.05 mg/m3 as an 8 hour time weighted average.
- Report exceedances: if a result is above the exposure standard, report it to the regulator as soon as reasonably practicable and within 14 days of receiving it, even if workers wore respirators.
- Health monitoring: provide it to workers with ongoing exposure that poses a significant risk, through a registered medical practitioner experienced in health monitoring. Send the regulator the report if it shows a silica-related disease or recommends remedial measures.
- Records: keep air and health monitoring records for 30 years, and silica training records while the worker does the work and for 5 years after they leave.
Where awareness training fits, and where it does not
Our courses are non-accredited short courses with a certificate of completion. They do not, on their own, meet the crystalline silica training requirement for high-risk work, which must be nationally accredited or regulator approved. NSW has published criteria that in-house or third-party courses can meet to count as regulator-approved training, so check your regulator's list first.
Awareness training still has a job. You must give information, instruction and training to anyone who may be exposed even when work is not high risk, and supervisors, estimators and office staff who book jobs need to know the ban and the notification rules. Pair it with our managing WHS risks course for the people who write your assessments, and track completions in a team training register.
What changed in 2026
Safe Work Australia reviewed the ban in 2024 and 2025. Its implementation plan, last updated in September 2026, responds to 6 recommendations and 11 findings. National testing criteria to decide whether a product is engineered stone are expected in 2027. Amendments to model regulations 529E and 529F to allow re-installation of legacy stone were expected to be finalised in 2026, and practical guidance on identifying banned products was expected by the end of 2026. Safe Work Australia and the Asbestos and Silica Safety and Eradication Agency launched a joint Be Silica Smart campaign in July 2026.
Exposure limits are also changing. From 01/12/2026, workplace exposure limits replace the workplace exposure standards. Ministers asked for more impact analysis on respirable crystalline silica before its limit is updated, so confirm the current figure with your regulator. Our airborne contaminants course covers the switch.
Common mistakes
- Assuming a stone alternative is safe because it is not banned. Any stone slab can release harmful dust when cut, so check the safety data sheet.
- Skipping the written high-risk assessment because the crew uses water.
- Lifting and refitting an old benchtop without checking the re-installation exemption.
- Treating a non-accredited online course as the silica training needed for high-risk work.
- Keeping monitoring results in a site folder that is thrown out when the job ends, instead of for 30 years.
Training that covers this
These DueCourse courses are non-accredited short courses with a certificate of completion.
Frequently asked questions
Is all stone banned in Australia?
No. The ban only covers engineered stone benchtops, panels and slabs with at least 1% crystalline silica. Natural stone, and porcelain or sintered stone without resin, are not banned, but cutting them can still release silica dust, so the silica duties apply.
Can a tradesperson remove an old engineered stone benchtop?
Yes. Removal, repair, minor modification and disposal of legacy engineered stone are allowed, but the processing must be controlled and, outside Victoria, the business must notify the WHS regulator first. Re-installing the same benchtop counts as installation, so check the exemption that applies in your state or territory.
Does an online silica awareness course meet the training requirement?
Not for high-risk work unless your regulator approves it. The regulations require crystalline silica training for high-risk processing to be nationally accredited or regulator approved. Awareness courses like ours help you meet the general duty to inform and train other workers who may be exposed.
How long do silica records have to be kept?
Air monitoring and health monitoring records must be kept for 30 years. Silica training records must be kept while the worker does high-risk processing and for 5 years after they stop working for you.
Sources
- Safe Work Australia: Engineered stone ban
- Safe Work Australia: Working with crystalline silica substances, guidance for PCBUs (August 2024)
- Safe Work Australia: Engineered stone prohibition review, implementation plan (September 2026)
- Safe Work Australia: Workplace exposure standard for respirable crystalline silica
- Safe Work Australia: New Workplace exposure limits (WEL) to apply from 01/12/2026
- SafeWork NSW: Crystalline silica technical fact sheet
Training for construction businesses Keep a team training register Pricing for teams